Start with the drawing, not a guessed spacing
Enter the rectangular slab, edge cover, bar size, layers and maximum spacing specified for the job. The calculator places bars at both cover lines and rounds the number of spaces up, so displayed actual spacing does not exceed the entered maximum.
Formula and useful comparison
Clear dimension equals slab dimension minus twice the cover. Bars parallel to a side equal ceil(clear perpendicular span ÷ maximum spacing) + 1. Total length sums both directions and layers, then applies your allowance. Compare another spacing to see its effect on counts, weight, stock equivalents and entered-price cost.
Independent checks
For a 16 ft × 12 ft slab, 3 in cover and 12 in maximum spacing, the clear grid is 15.5 ft × 11.5 ft. The conservative layout uses 13 lengthwise and 17 widthwise bars: 397 ft before allowance. Five percent gives 416.85 ft, about 278.456 lb of #4 bar and 21 theoretical 20 ft equivalents. A 6 m × 4 m grid at 40 cm and 8 cm cover uses 11 and 16 bars, totaling 125.68 m before allowance.
Interpretation, mistakes and limits
Stock equivalents are a purchase screen, not a cutting or lap-splice plan. The model does not design reinforcement or choose bar size, spacing, cover, development length, hooks, chairs, ties or strength. Those inputs must come from approved drawings and applicable codes. Weight is nominal; supplier tolerances and fabrication can differ.
Official source
CRSI Ready Reference identifies ASTM bar sizes, diameters, areas and nominal weights. Verify current project specifications and supplier data.