Turn a measured liquid depth into a working volume
Choose a rectangular, upright cylindrical or horizontal cylindrical tank and enter internal dimensions. The core result shows current volume, percent full, the amount to fill or drain to a target depth, and time at the entered constant flow. This is a tank-level task, not just another solid-volume alias.
Formula and decision flow
Rectangular volume is L×W×h and vertical-cylinder volume is πr²h. For a horizontal cylinder at liquid depth h, segment area A=r² arccos((r−h)/r)−(r−h)√(2rh−h²), then volume=A×length. Change volume is target minus current; time is its absolute litres divided by litres per minute.
Independent checks
A 2 m×3 m×4 m rectangular tank at 1 m holds 6 m³ (6,000 L), or 25%; reaching 4 m adds 18,000 L and takes 180 minutes at 100 L/min. A vertical cylinder 2 m in diameter and 4 m high is half full at 2 m: 2π m³. A horizontal cylinder 2 m in diameter and 4 m long is also exactly half full at 1 m: 2π m³.
Input mistakes, interpretation and limits
Use internal dimensions and one length unit. Zero depth is valid; zero dimensions or flow, negative depths and depths above the tank are rejected. Flat ends, level installation and constant net flow are assumed. Dished heads, tilt, wall thickness, internal obstructions, unusable heel, fittings, pump head, leakage and changing flow are excluded. Use a certified strapping or calibration table for custody transfer.
Sources and measurement limits
NIST SI Units – Volume supports the SI volume units, and NIST Handbook 44 liquid-measuring guidance explains why commercial measurement requires suitable equipment and calibration.