Calculate roof pitch, angle and sloping length, then estimate surface area and a custom allowance from the horizontal footprint.
Enter your values
Calculations run on your device; inputs are not sent to our server.
From footprint to sloping surface
Use the horizontal projected area covered by the measured slope. For a whole roof, this shortcut requires every included plane to have the same pitch. Enter square metres or square feet to match the length unit above.
Examples replace the inputs above. Use Reset values to restore defaults.
Check the measurements before ordering
Rise 3 m and run 4 m form a 3–4–5 triangle. Pitch is 9:12, grade 75%, angle about 36.8699°, and surface/footprint factor 5/4 = 1.25. A projected area of 80 m² becomes 100 m² of sloping surface; an illustrative 10% allowance adds 10 m² for a total of 110 m².
Do not enter sloping surface area as projected area: multiplying it again double-counts the pitch. For a symmetric gable with a full span of 8 m, the run to the ridge is 4 m, not 8 m. Measure overhang separately; the calculator does not add it.
The allowance is a user-supplied planning percentage, not a recommended waste rate. Packaging, overlaps, valleys and cutting layout can change an order. Flat geometry is accepted as a mathematical boundary, not proof that a roof has adequate drainage. This tool does not check structural safety or building-code compliance.
Run is the horizontal distance for the measured rise. On a symmetric gable roof it is half the full span, before any overhang. Enter both measurements in the same selected unit. Changing the unit label reinterprets the numbers; it does not convert them.
Formulas and example
Pitch = 12 × rise/run. Angle = atan(rise/run). Grade = 100 × rise/run. Sloping length = √(rise²+run²). Rise 1 m and run 2 m give 6:12, 26.565051°, 50% and 2.236068 m.
Geometry, not a roof design
The length excludes overhang, ridge-board adjustments, birdsmouth cuts and construction tolerances. Roof area factor applies to one planar slope. This does not check loads, drainage, building codes or material suitability; verify construction dimensions with a qualified professional.